6W Wall Mount Charger with 100 to 240V AC Input Voltages and 0.04% Maximum Temperature Coefficient

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-15 20:34

  • Browse the number:

    47

Send an inquiries
+
Eljintek Inc
Contactaixin:

Contactaixin:

eljintek(Ms.)  

telephone:

Area:

Beijing

Address:

6F-1, No. 286-3 Shin-Ya Road, Chien-Chen District, Kao Hsiung, Taiwan (806)

Website:

http://eljintek.pt-my.com/

+
Model Number: GPSU06SA-X-CC(CBC) Brand Name: eljintek Key Specifications/Special Features: Input voltages: 100 to 240V AC (90 to 264V AC limits) and 50 to60Hz (47 to 63Hz limits)Input current: 0.2A maximumOutput voltage: see rating chartOutput current: see rating chartOutput power range: see rating chart
  • Ripple: 1% peak to peak maximum (see rating chart)
  • Over-voltage protection: supported, provided by Zenerdiode
  • Over-current protection: supported, auto-recovery
  • Standard series: rated output current greater than 110% forprimary referenced direct drive
  • Temperature coefficient: all outputs ± 0.04%maximum
  • Transient response: maximum excursion of 4% or better on allmodels recovering to 1% of final value within 500S after a25% step load change
  • Operating temperatures: 0 to 40°C see derating curve
  • Storage temperatures: -40 to 85°C
  • Relative humidity: 5 to 95% and non-condensing
  • Derating: derated from 100% at 40°C linearly to 70% at50°C
  • Average efficiency: see rating chart
  • Setup up, hold-up and rise time: (typical) 3,000, 16 and 50m/sat full load
  • Line regulation: ±1% maximum for any input voltagechange between input voltage range
  • Load regulation: typical ±5% variation from minimum tomaximum output current
  • Insulation resistance: 50M minimum from input toground
  • In-rush current: 30A at 115V AC or 60A at 230V AC at 25°Ccold start
  • Withstanding voltage: 4,242V DC from input to output
  • Meantime between failure: 100,000 hours minimum at full load at25C ambient temperature
  • EMI requirements:
  • CE Emission: EN55022, EN61000-3-2-3
  • Immunity: IEC61000-4-2, 3, 4, 5, 6 and 11 (B) FCC 47 CFR part15 subpart B.ICES-003 issue 4 ANSI C63.4-2003
  • Safety requirements meets or exceeds: UL 60950-1, CSA-C22.2,EN60950-1 and IEC60950-1
    • Characteristics:
    • Universal input voltage
    • Single output
    Main Export Markets:
    • North America
    • Eastern Europe
    • Mid East/Africa
    • Central/South America
    • Asia
    • Western Europe
    • Australasia

    Download more information about this product